A beam-matching concept for medical linear accelerators

    https://pubmed.ncbi.nlm.nih.gov/18752079/
    The measured absorbed dose data for each accelerator were compared with the first accelerator, chosen as reference, and the TPS calculations. Two of the eight accelerators showed a larger discrepancy for the 15 MV beam not revealed by the vendor-defined …

A beam-matching concept for medical linear accelerators

    https://www.tandfonline.com/doi/full/10.1080/02841860802258794
    Following the CAP more extensive commissioning measurements were undertaken (Tables I and II) in view of the fact that; (i) the vendor-defined criteria does not …

A beam-matching concept for medical linear accelerators

    https://www.tandfonline.com/doi/pdf/10.1080/02841860802258794
    to beam-matched accelerators only one set of data representing all the accelerators needs to be imple-mented in the treatment planning system (TPS). Due to the strict …

A beam-matching concept for medical …

    https://www.researchgate.net/publication/23218718_A_beam-matching_concept_for_medical_linear_accelerators
    In our center four beam-matched Elekta™ linear accelerators were installed, which consists of …

A beam-matching concept for medical linear accelerators

    https://www.osti.gov/etdeweb/biblio/947677
    The beam-matching acceptance criteria defined by the vendor are not strict enough to guarantee optimal beam-match. Deviations related to dose calculations and to …

A beam-matching concept for medical linear accelerators.

    https://europepmc.org/article/MED/18752079
    Europe PMC is an archive of life sciences journal literature. A beam-matching concept for medical linear accelerators.

Equivalency of beam scan data collection using a 1D …

    https://aapm.onlinelibrary.wiley.com/doi/full/10.1002/acm2.12444
    3.B Beam modeling To quantify the differences in the two beam models created (BM 1DS and BM 3DS ), beams of various field sizes were calculated on a water …

A beam-matching concept for medical linear accelerators|INIS

    https://inis.iaea.org/search/search.aspx?orig_q=RN:40019883
    The flexibility in radiotherapy can be improved if a patient can be moved between any one of the Department's medical linear accelerators without the need to change anything in …

Beam matching of two linear accelerators, …

    https://www.researchgate.net/publication/342206999_Beam_matching_of_two_linear_accelerators_identical_model_and_brand
    All beam matching parameters from our two LINACs are comparable and acceptable value approximate ±1% or less for both photon and electron beams; …

Dosimetric analysis of beam-matching procedure of two similar …

    https://www.semanticscholar.org/paper/Dosimetric-analysis-of-beam-matching-procedure-of-Bhangle-Narayanan/b0cd9caa84e9c0dc5db260ac49bafcd4a523506e
    All these films have shown good agreement for - Δdistance of 3 mm and Δdose of 3 %. Different tests done after commissioning are described to evaluate the level of …